We attended a home where the boiler wasn’t reaching full output and was experiencing low gas pressure issues.
After testing, we discovered low working pressure at the appliance, caused by undersized gas pipework over a long run. This was restricting the gas supply and preventing the boiler from operating at full performance.
🔧 The solution?
We installed new, correctly sized gas pipework to meet the boiler’s full gas rate requirements. The result? Working pressure restored and full boiler performance back where it should be!
We also used steel pipework for the external section. Why steel?
✅ Built to last – Strong and durable, offering excellent resistance to knocks and harsh weather.
✅ Corrosion and UV resistant – Suitable for external use when correctly specified and installed, without the same UV degradation concerns.
✅ A compliant, professional installation – External gas pipework must use suitable materials and be installed in accordance with the relevant regulations.
No more pressure drops or a boiler struggling to perform – just a properly sized gas supply and a system working as it should! 🔥 If your boiler isn't performing, taking ages to heat up, or you've been told you have low gas pressure - it might not be the boiler, it might be the pipe feeding it.